System Sensors AV notification devices are the most versatile, easy to install, and cohesive line of audible visual (AV) notification appliances in the industry. System Sensor warrants its enclosed smoke detector to be free from defects in materials The System Sensor 2W-B is a 2-wire smoke detector and a member of System Sensors i3 Series of photoelectric smoke detectors. 2W-B - Honeywell System Sensor 2-Hardwired Smoke Detector - AlarmClub Visit systemsensor.com for current product information, including the latest version of this data sheet. Do you see that white unit anywhere in or near your 20P alarm panel? With less intelligent smoke detectors, a dirty photoelectric chamber will results in false alarms. applicable. Detectors may remain in operation provided they continue to pass the regular testing. Add the hardwired 2W-B smoke detector to most existing alarm system control panels. It would be hard to rate this product at one star unless it was somehow responsible for an unreported house fire. 2WTR-B - SYSTEM SENSOR - i3 Series | Anixter Features include a universal mounting plate with a preliminary snap-in feature to hold the product in place for the screw attachment, 7 field-selectable candela settings for wall and ceiling mount devices, and rotary switches to select horn tone and volume settings. This chart contains the current list of detectors and UL Listed compatible control units. As long as they operate at 12 Volts DC, they should work. Buy the System Sensor 2WTA-B Smoke and Heat Sensor from Alarm Grid. Direct mount or to ceiling using drywall fasteners (Figure 2). I see other smoke detectors that claim a lifespan of 10 years and recommend replacement at that time. I will say that it came packaged correctly and it functions as designed, would buy again. This includes cleaning, maintenance or screen replacement. 2. I recommend powering down the system and placing your system on test mode if monitored before swapping in the new smoke. System Sensor BK-2WB Photoelectric i3 Series Smoke Detector, 2-Wire, White Brand: System Sensor ADI #:BK-2WB Model #: 2W-B Name: System Sensor BK-2WB Photoelectric i3 Series Smoke Detector, 2-Wire, White Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Product Overview Installation ease. Z@~P]%*?p S_iVN$rtE;[\SmgisL^aOTYVE \xOQc_m1eN"hB~n5#{f-!tEn -:)D#bBc7yo0x&i9Su%t wa+"i System Sensor 2W-B Product Specifications: System Sensor 2W-B Product Compatibility: Plug-in detector line, mounting base included, Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling, Drift compensation and smoothing algorithms. of smoke detectors. System Sensor is not selling, supporting or endorsing AFMGs EASE Evac voice evacuation software. NOTE: To install units so that corresponding LEDs are lined up, refer to the Place detector on the base and rotate clockwise. Operating Temp. 4. To view our listings, please visit one of the following sites. 6.3 oz. Min. In no case shall the Company be liable for any consequential or incidental damages for No Contract Alarm Monitoring starting at $10 a month! Refer to Series detectors are designed to provide open area protec-, tion. accept any interference received, including interference that may cause undesired operation. All wiring must be installed in compliance with the National Electrical Code, the use of a mounting base that may be pre-wired to the system, allowing the A. sensitivity back to the factory setting when it becomes more sensitive due to The After all detectors have been installed, apply power to the alarm control I have since replaced the battery, which has resolved the smoke error. HyperSpike speakers offer revolutionary sound quality and intelligibility for fire and life safety applications and their innovative designs exceed the highest standards in military and acoustic notification markets. Start-up Time: Product specifications subject to change without notice. If the detector is in need of maintenance because its sensitivity has shifted outside the listed limits, the red LED blinks once every five seconds. *Refer to Electrical Specifications for start-up time in conjunction with panel alarm verification. Smoke detectors are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose. Near fresh air inlets or returns or excessively drafty areas. 0 20 mA 12 Volt Systems Developed and delivered by Honeywell industry experts, HBU training employs techniques and technologies to help your teams learn everything they can about our products. Wiring Diagrams Fill out our feedback form! down firmly until the screen/sensing chamber is fully seated. In order for this feature to work properly, the chamber must never be opened while power is applied to the smoke Alarm Contact Ratings: Please send an email to support@alarmgrid.com referring to this inquiry to better assist you with your 20P. %%EOF 2WTA-B - System Sensor - JMAC PDF System Sensor L-series indoor horn/strobes performed and the system will be temporarily out of service. Just fill out the form and click your area of interest. System Sensors AV notification devices are the most versatile, easy to install, and cohesive line of audible visual (AV) notification appliances in the industry. or damage is caused by the Companys negligence or fault. 2W-B - System Sensor - JMAC Please include a For two-wire models Installation of the 2W -B, 2WT -B, 4W -B, and 4WT -B detectors is simplified . Certain System Sensor SWIFT AV bases have the potential to generate a premature and erroneous low battery notification. fasteners. Explore System Sensor products including: AV Notification, Beam Smoke detection, CO detection, HVAC Smoke detection, spot smoke detection, relays, & modules. Wiring Installation Guidelines FREE delivery Mar 8 - 10. Follow the steps in the Tech Bulletin below to check your current firmware version and update your device firmware if needed.. A copy of this list is available from System Sensor upon request. Access all of System Sensor's tools and software offerings. to the plastic. Insert a small screwdriver or allen wrench (0.18 max.) Peak Standby Current: honeywell smoke detector wired INSTALLATION AND MAINTENANCE INSTRUCTIONS. any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". Standby Current: It should connect the same exact way. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. System Sensor 2W-B - FireAlarm.com In order for this feature, to work properly, the chamber must never be opened while. 2W-B Datasheet (HTML) - Systemsensor advanced ideas. of a 2W-MOD2 module. Thanks for using Alarm Grid as a resource.For the purpose of improving our site, wed like to know if you are one of the following: INSTALLATION AND MAINTENANCE INSTRUCTIONS, Series 5. System Sensor makes no other express warranty for this smoke detecbe obligated to repair or replace units which are found to be defective because of damage, To calculate performance-based strobe coverage, the inverse square law is used to calculate the illumination at each of the angles in the horizontal and vertical planes per ANSI/UL 1971, Standard for Signaling Devices for the Hearing Impaired, and the effect of polar distribution is included using the minimum percentages in ANSI/UL 1971 or actual test results recorded by the Listing organization. switch opening; push and hold. Leave everything as is at the panel and simply replace the smoke detector itself. Physical Specifications from the end of the feed wire, inserting it into the proper base terminal, and its listed sensitivity range, the green LED blinks once every five seconds. The mounting base installation is further simplified by. Table 3: EZ Walk Test Detector Modes 32 to 120F (0 to 49C) Air conditioners, heaters, fans, and fresh air intakes and returns can drive smoke away from the detector. System Sensor 2451 A Photo B401B / B406B / DH-400 / B110LP / B116LP A 120 System Sensor 2451TH A Photo / Therm. Its simple, step-by-step process makes it easy for users to configure panels and circuits from a variety of devices. When used with an i3 Series compatible control panel or the i3 Series 2WMOD module (refer to installation manual D500-46-00), the 2W-B and 2WT-B System Sensors intelligent and conventional modules are designed to help you meet a wide range of application requirements. 2. When the sensing chamber gets too dirty and the 2W-B is no longer calibrated to the proper sensitivity, the smoke detector will alert you with a red LED that blinks every five seconds so that you can perform the necessary maintenance. It can connect with a Honeywell VISTA System at Zone 1. You have been registered for product and offer updates. St. Charles, Illinois 60174. Subscirbe to specific System Sensor email communications. indicate a need for cleaning, replacement, or a fr eeze condition (2WT -B only) at the control panel or module. into the base and lock into place with a click. r^ lC-kr$EG_ KD/T=[ $y`j"lOmX LX6F(F;x*+yj#xgUB?fH"U*zN84Vz D~m$y:67HqwZJ:RSYk4MU=';W(pg|s[pJTW/X '@GWSYm }Fs Copyright 2023 Honeywell International Inc. REMOVABLE Power-up item 1 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector. unreasonable use, modifications, or alterations occurring after the date of manufacture. These calculations are described in NFPA 72 and are to be provided to the authority having jurisdiction. System Sensor tools include a variety of software, drawings and calculators to help you effectively plan and prepare for your next fire safety system installation. When the detector is in the alarm mode, the red LED latches on. In a freeze, trouble condition, the red LED will blink once every 10 seconds, To measure the detector's sensitivity, the i, RDR Infrared Sensitivity Reader tool (see Figure 4) should be, Models 2W-B and 2WT-B also include an output that allows an. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must Storage Temperature Range: Our hardwired CO detectors with RealTest use electrochemical sensors to measure carbon monoxide levels and alert residents with a flashing Temp-4 signal alarm. The calculation points are in the horizontal and vertical planes in 5 degree increments per UL 1971. Operating Temperature Range: Some states do not allow the It should be straightforward if you do not need to wire the back plate. 4.8 out of 5 stars based on 20 product ratings, 4.8 out of 5 stars based on 166 product ratings, 4.9 out of 5 stars based on 174 product ratings, 4.8 out of 5 stars based on 175 product ratings, 4.8 out of 5 stars based on 190 product ratings, 5.0 out of 5 stars based on 1 product rating. When using the System Sensor 2W-B two wire smoke detector with a VISTA-20P or VISTA-21iP alarm control panel, you should wire the smoke detector to zone one. 41F (5C) Tamper-Resistant Feature D initiating circuits require the use of a 2W-MOD for models 2W-B and 2WT-B. To measure the detectors sensitivity, the i3 Series Model SENSRDR Infrared Sensitivity Reader tool (see Figure 4) should be used. Thank you for the response @disqus_YuNiL6S1Rn:disqus. This feature ensures that your security system will not experience nuisance false alarms. The Companys obligation Consult NFPA 72, the local Authority Having Jurisdiction (AHJ), and/or applicable codes for specific information regarding the spacing and placement of smoke detectors. POSITION SENS-RDR System Sensor offers world-class fire detection and notification solutions System Sensor Founded in 1984, System Sensor is a global manufacturer of fire and life safety devices, specializing in smoke detection, carbon monoxide detection, and notification technology for world-wide applications. Height (including base): When used with an i3 Series compatible control panel or the i3 Series 2W-MOD module (refer to installation manual D500-46-00), the 2W-B and 2WT-B are capable of generating a maintenance needed signal. This includes cleaning, maintenance or screen replacement. prevent a system from responding properly in the event of a fire. Near fresh air inlets or returns or excessively drafty areas. This feature is w responsible for an unreported house fire. Improper connections can prevent a system from responding properly in the event of a fire. (For 2W-B and 2WT-B, panel must limit current) This equipment generates, uses and can radiate radio frequency energy and, if not installed and used To a 312-inch or 4-inch octagonal box, or To engage the tamper-resistant feature, cut the small plastic tab located on the mounting base (Figure Each zone provides enough stand by current (2ma) to power up to sixteen smoke detectors. 2-Wire i3 Detector Wired in Style D Configuration: B. $59.99. Compatible with 12- or 24-volt systems. It sounds like you may be experiencing a low battery issue possibly. Any 2-wire i3 smoke detector (2W-B, 2WT-B, 2WTA-B, or 2WTRB) wired PDF Selectable-Output Horns, Strobes, and Horn Strobes 4. To measure the detectors sensitivity, the i3 Series Model SENS-RDR Infrared Solid, After an initial power-up delay, the red and green LEDs will blink synchronously once every ten seconds. z7$m9ymnsx.}]{~{^^}ltW? Fire Alarm Systems | System Sensor L-series indoor horn/strobes System Sensor L-series indoor horn/ strobes www.boschsecurity.com u u Plug-in design with minimal intrusion into the back box u Field-selectable candela settings of 15 or 30 cd at 12 V or 15, 30, 75, 95, 110, 135, and 185 cd at 24 V u Horn rated at 88+ dBA at 16 V Rotary switch for horn tone and two volume settings Models 2W-B and 2WT-B also include an output that allows an optional Model RA400Z Remote Annunciator to be connected. System Sensor products are designed and manufactured to meet or exceed various product safety and certification requirements. 50 Explore System Sensor products including: AV Notification, Beam Smoke detection, CO detection, HVAC Smoke detection, spot smoke detection, relays, & modules. Hold a smoldering punk stick or cotton wick at the side of the detector and Do these detectors have a similar lifespan? Reinstall the detector and test. I am not of the exact model number of the existing 2-wire smoke detector so I cannot say for sure if the back plates are the same. In very cold or very hot areas. InnovairFlex duct smoke detectors combine an impressive collection of innovations to greatly simplify HVAC system monitoring. 23 mA 24 Volt Systems The heads and bases are clearly identified as either 2-wire or 4-wire. Developed and delivered by Honeywell industry experts, HBU training employs techniques and technologies to help your teams learn everything they can about our products. Podcast; Latest In dusty, dirty, or insect-infested areas. 2WT-B and 4WT-B: Smoke Detectors with Sounder and Relay Option To engage the tamper-resistant feature, cut the small plastic tab located on the mounting base (Figure 2), and then install the detector. For best system performance, all wiring should be installed in separate grounded conduit; do not mix fire alarm system wiring in the same conduit as any other electrical wiring. in the Style D initiating device circuit (IDC) configuration requires the use Blink 5 sec monoxide(co)/photoelectric smoke detector (4 pages), Manual will be automatically added to "My Manuals", Installation and maintenance instructions, Smoke Alarm System Sensor 4WT-B Installation And Maintenance Instructions, Smoke Alarm System Sensor 2WT-B Installation And Maintenance Instructions, Smoke Alarm System Sensor 2WTR-B Installation And Maintenance Instructions, Smoke Alarm System Sensor 2100ARFT Installation Instructions Manual, Smoke Alarm System Sensor 2251EIS Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor 22051E-RF Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor 2112 Installation And Maintenance Instructions, Smoke Alarm System Sensor FSB-200 Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor BEAM1224 Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor 2351E Installation And Maintenance Instructions, Smoke Alarm System Sensor DH100ACDCLP Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor 2100AT Installation And Maintenance Instructions, Smoke Alarm System Sensor 6500S Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor i4 Series COSMO-2W Installation And Maintenance Instructions, Smoke Alarm System Sensor Innovair flex D4120A Installation And Maintenance Instructions Manual. Each i3 Series detector is supplied with a mounting base that can be Freeze Trouble (Model 2WT-B and 4WT-B): spacing, placement, zoning, wiring, and special applications. Consult the dealer or an experienced radio/TV technician for help. Remove the top half of the screen/sensing chamber by lifting straight up If a detector fails any of the above test methods, its wiring should be checked RA400Z Remote Annunciator to be connected. However, the i3 Series smoke detector allows for fast and easy inspection. : 1. The 2W-B smoke detector is not the typical conventional detector. NOTE: Before testing, notify the proper authorities that maintenance is being View a list of all System Sensor locations worldwide. best system performance, all wiring should be installed in separate grounded Copies of this I have a DSC alarm system that my current System Sensors are connected to and would I need to do anything special when I replace the old with the new other then reset the system? I will say that it came packaged correctly and it functions as designed, would buy again. System Sensor 2W-B Photoelectric i3 Smoke Detector, 2-Wire, System Sensor P4W-P Horn Strobe, White, Wall Mount, Four-Wire, System Sensor PC2W Horn Strobe, White, Ceiling Mount, Two-Wire, FIRE Lettering, System Sensor B210LP Detector Base, Plug-In, System Sensor 2151 Photoelectronic Low-Profile Plug-In Detector for Special Applications, System Sensor SCWL Strobe, Ceiling Mount, FIRE, White, Clear Lens, System Sensor EOLR-1 End-of-Line Epoxy Encapsulated Relay, SPST, Plug-in detector line, mounting base included, Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling, Drift compensation and smoothing algorithms. heaters, or gas space heaters. for System Smoke Detectors, which provides detailed information on detector The CLSS Tool Suite allows you to perform battery, voltage drop, and Db line loss calculations in a single desktop application. Lets you hear all the different audio tones of the AV notification appliances, such as the temporal 3 and non-temporal for the electromechanical, 3.1KHz, 520Hz, as well as the chimes. The calculator was programmed to assist you in the design of audible/visible notification device circuits. The 2W-MOD can indicate a need for cleaning, replacement, or a freeze condition (2WT-B only) at the control panel or module. Do NOT Install Detectors in the Following Areas: Unlike traditional detection systems, Reflected Beam Smoke Detectors were designed for spacious rooms, open areas, and high ceilings; their innovative features make them popular choices for spaces like warehouses, atriums, arenas, and churches. This item: System Sensor 2W-B i3 Series 2-wire, Photoelectric i3 Smoke Detector $52.42 UHPPOTE Wired Sound and Light Fire Alarm Warning Strobe Siren Horn Sound Alert Safety System $18.40 Fire Lite Alarms Dual Action Pull Station w Key Lock $57.06 Honeywell VISTA-20P Ademco Control Panel, PCB in Aluminum Enclosure 399 12 offers from $73.62 Table 2: Power-up Sequence for LED Status Indication*, (if excessive electrical noise is present), *Refer to Electrical Specifications for start-up time in conjunction with panel alarm, NOTE: If, during power-up, the detector determines there is, excessive electrical noise in the system such as those caused by, improper grounding of the system or the conduit, both LEDs will, blink for up to 4 minutes before displaying detector status (see, After power-up has completed and the detector is functioning, normally within its listed sensitivity range, the green LED blinks, once every five seconds. 21. exclusion or limitation of incidental or consequential damages, so the above limitation electrical wiring. away from the detector. DETECTOR Please read thoroughly System Sensor manual A05-1003, Applications Guide System Sensors intelligent and conventional modules are designed to help you meet a wide range of application requirements. 1015 0 obj <>/Encrypt 1001 0 R/Filter/FlateDecode/ID[<493E40FFCF1D3F747B74E48D03207C10>]/Index[1000 51]/Info 999 0 R/Length 93/Prev 198552/Root 1002 0 R/Size 1051/Type/XRef/W[1 3 1]>>stream item 8 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector, 5.0 out of 5 stars based on 9 product ratings. *Assumes the panels alarm verification reset time is 10 seconds or less. at the control panel or module. You can use up to sixteen 2W-B smoke detectors on the zone one fire loop. For the effect of polar distribution (rated candela at each angle), the ANSI/UL 1971 minimum percentages are used for the calculations. Compatible Brand. System Sensor | Honeywell Building Technologies 4 to 158F (20 to 70C) 4-Wire Smoke Detector with 135F Fixed Heat Sensor, 2-Wire Smoke Detector with Fixed Heat Sensor, System Sensor 2W-B, 2WT-B, 4W-B & 4WT-B - Installation Guide. In wet or excessively humid areas, or next to bathrooms with showers. I am wondering if there is too much power connected to the panel for the sirens to sound. Ready to learn more? alarm verification. Turn on: 1. Ensure proper wiring and power is applied. tor. 5.3 inches After power up, allow 80 seconds To stay in the know on upcoming news and announcements, subscribe. Should the alarm verification reset exceed 10 seconds, use the maximum initial start-up time. 3825 Ohio Avenue The i3 Series detectors include a tamper-resistant feature that prevents removal from the mounting base without the use of a tool. Gray. needed" signal. Replace the detector cover by placing it over the screen/sensing chamber (Figure 5). Wd]_c'F1p% Alarm Current: